About us

HELANTEC has its origins in gas analysis. This is why we are the specialists in the area of gas technology. Thanks to our knowledge of gases, their behaviour and characteristics, we have developed a broad spectrum of products and solutions for a

Products and services

Market leader in gas filling and gas testing for the insulation glass industry.

Gas filling machine

Gas analyser

Gas press monitor

Pressure adjustment

Worldwide, HELANTEC is the first address in the insulated glass industry for manual gas filling technology and gas concentration determination.

HELANTEC has its origins in gas analysis. This is why we are the specialists in the area of gas technology. Thanks to our knowledge of gases, their behaviour and characteristics, we have developed a broad spectrum of products and solutions for a wide variety of applications. HELANTEC is always your first contact wherever processes with gas must be regulated, monitored, visualised, and analysed. In recent years, documentation of gas filling processes has become a centre of focus.

RAPIDE L500

The RAPIDE L500 is the top selling gas filling system with fast-fill technology!
This gas filling system has proven itself for many years and represents the state of the technology. The investment volume of the system is unrivalled in terms of capacity.
The RAPIDE L500 is more than "just" a manual gas filling system. With the integrated IPC the gas filling process is visualised and automatically documented. Only with this product do you have a verification of quality for all filling processes.

Further reading

Helox 4

The HELOX 4 has been a proven test instrument for quality control of IG units for more than 20 years. The analyser is preferred by test institutes and the central labs of the insulated glass manufacturers.
A paramagnetic measuring cell that selectively measures the residual oxygen, and which consequently is the primary measurement method, is used as the measuring technology for this analyser. On the display the gas concentration of the gas sample is shown.

Further reading

IGM / IPA process monitor

The economic success of modern insulated glass production significantly depends on 3 factors:

- uniform, assured quality
- optimal, systematic use of all resources (time, material, equipment availability)
- compliance with statutory regulations (CE mark, EN 1279, documentation, etc.)
Currently, at least 1% of production must be checked and documented relative to gas concentration. At the same time however the producer must guarantee the assured characteristic for each individual product (100%).

Further reading

Address
Helantec GmbH
Werner-von-Siemens-Str. 47a
76646 Bruchsal
GERMANY

Phone: 0725185731
Internet: www.helantec.de
E-mail: Send message

Contact person

Gregor Witrofsky
GM
Phone: +49 176 42618877
E-mail: Send message

Representative
Joint Pacific Beijing Ltd
Room 1403-1404, Machinery Building,
Beijing, 100055
China

Phone: 010-63362071
Internet: www.jpbl.net
E-mail: Send message

News & Innovations

ISO-Altimeter professional Adjust the IG unit for the atmospheric pressure of the installation place
With the ISO-Altimeter PROFESSIONAL the IG unit is prepared in production in such a manner that it is flat at the higher altitude or lower altitude of the installation site. Additional after-treatment is not required!
The ISO-Altimeter PROFESSIONAL is the further development of our proven predecessor model. Intuitive operation via touch screen, clear user guidance and versatile functions are only a few of the features that characterise our pressure balance system.
Other special characteristics:
To achieve short cycle times, there has been a conversion to completely new technology. This enables us to execute the pressure balance with the highest accuracy and within the shortest time possible. To avoid operating errors, all data required for the pressure balance is loaded automatically from a list. The most efficient procedure is simply scanning a barcode on the IG unit.

Further reading
Handheld GasTester
The GAS TESTER is our lowest-price entry-level model for monitoring gas concentration. Naturally we have installed our proven analysis technology in this product as well.

Features

reliable concentration measurements
compact and handy design
easy operability
Only a small quantity of gas is required. Sampling is executed with a special gas supply pump. The GAS TESTER is suitable for quality control of IG units with argon as the filling gas. If you desire to also analyse other gas types or gas mixtures, you should chose one of our other analysers.

We would be pleased to advise you in the selection of a suitable analyser for your requirements.
Further reading
Production control for gas presses
Currently, at least 1% of production must be checked and documented relative to gas concentration. At the same time however the producer must guarantee the assured characteristic for each individual product (100%).
In this regard, delimitation of risk is of central significance. Faulty products often cause undesired economic consequences and not infrequently result in sustained damage to the company’s image.
It is precisely at this point that present handling differs from the requirements of the market. This is where HELANTEC offers you the perfect solution.

Only HELANTEC makes it possible to visualise, monitor and document the gas filling process for gas filling presses

IGM/IPA
• monitors and visualises
- the gas filling process of each manufactured IG unit
- the gas type
- distribution of the gas during the filling process
• signals
- direct deviations from the setpoint (early warning)
- deviations in consumption
• documents the filling procedure
• presents a diagnostics aid (visualisation)
Further reading

Click here if you notice an image that violates copyright or privacy rights.

Get in contact